Series IEF Insertion Electromagnetic Flow Transmitter

Field Configurable, High Accuracy, BACnet or Modbus® Protocol

A-IEF Remote Display is NOW AVAILABLE!

The Series IEF Insertion Electromagnetic Flow Transmitter is an adjustable insertion flowmeter featuring electromagnetic technology that accurately and reliably measures fluid velocity in addition to providing several continuous signal outputs. This series is specifically designed to offer superior performance paired with simple installation and use. One unit is adjustable to fit pipe sizes from 4 to 36" (101.6 to 914.4 mm), and offers several output options including selectable BACnet MS/TP or Modbus® RTU communications protocol over 2-wire RS-485 in addition to the standard analog, frequency and alarm outputs.

California Residents:  Click Here for Proposition 65 WARNING.

Product Applications

  • Boiler feed water
  • Chilled water
  • Open and closed loop condenser water
  • Irrigation system
  • Municipal water distribution
  • Process and coolant flow
  • Ground water remediation
  • Chemical processing
  • Pump protection
  • Wastewater
  • Mining

Models & Ordering

Filter By

Shipping Information

All shipping times are dependent on product availability at time of shipment.

Although we make every effort to ensure a continuous supply of our products, occasional circumstances may force us to temporarily run out of a product, or have shipping delays. Should this occur, customers will be notified soon after placement of any orders for such products and, if applicable, items will be put on backorder. For orders requiring expedited shipment, our customer service team can be contacted to confirm product availability

Build Your Custom Part. Use our Product Configurator

Model Description Usually Ships* Price Order
IEF-GB-PG-COM
Ships: Less Than 1 Week
Price: $2,650.00
Insertion Electromagnetic flow transmitter, >10-36" (250-900 MM) pipe, standard accuracy 1% FS, 1" male BSPT process connection, PG gland, BACnet/Modbus® output Less Than 1 Week* $2,650.00 Order
IEF-GN-CND-COM-LCD
Ships: 1-2 Weeks
Price: $3,030.00
Insertion Electromagnetic flow transmitter, >10-36" (250-900 MM) pipe, standard accuracy 1% FS, 1" male NPT process connection, 1/2" female NPT conduit connection, BACnet/Modbus® output with LCD display 1-2 Weeks* $3,030.00 Order
IEF-LB-PG-COM
Ships: Next Day
Price: $2,650.00
Insertion Electromagnetic flow transmitter, 4-10" (100-250 MM) pipe, standard accuracy 1% FS, 1" male BSPT process connection, PG gland, BACnet/Modbus® output Next Day* $2,650.00 Order
IEF-LN-CND
Ships: Next Day
Price: $2,194.00
Insertion Electromagnetic Flow Transmitter, 4-10"(100-250 MM) pipe, standard accuracy 1% FS, 1" male NPT process connection, 1/2" female NPT conduit connection Next Day* $2,194.00 Order
IEF-LN-CND-COM
Ships: Next Day
Price: $2,650.00
Insertion Electromagnetic Flow Transmitter, 4-10"(100-250 MM) pipe, standard accuracy 1% FS, 1" male NPT process connection, 1/2" female NPT conduit connection, BACnet/Modbus® output Next Day* $2,650.00 Order
IEF-LN-CND-COM-LCD
Ships: Less Than 1 Week
Price: $3,030.00
Insertion Electromagnetic flow transmitter, 4-10" (100-250 MM) pipe, standard accuracy 1% FS, 1" male NPT process connection, 1/2" female NPT conduit connection, BACnet/Modbus® output with LCD display Less Than 1 Week* $3,030.00 Order
IEF-LN-CND-LCD
Ships: Next Day
Price: $2,574.00
Insertion Electromagnetic Flow Transmitter, 4-10"(100-250 MM) pipe, standard accuracy 1% FS, 1" male NPT process connection, 1/2" female NPT conduit connection, LCD display Next Day* $2,574.00 Order
IEF-SB-PG-LCD
Ships: Less Than 1 Week
Price: $2,765.00
Insertion Electromagnetic flow transmitter, standard accuracy 4-36" (100-900 mm) pipe, 1% FS, 1" male BSPT, pg gland without cable with LCD display Less Than 1 Week* $2,765.00 Order
IEF-SB-PG-LCD-COM
Ships: 1-2 Weeks
Price: $3,221.00
Insertion Electromagnetic flow transmitter, standard accuracy 4-36" (100-900 mm) pipe, 1% FS, 1" male BSPT, pg gland without cable, BACnet/Modbus® communication output with LCD display 1-2 Weeks* $3,221.00 Order
IEF-SN-CND
Ships: Next Day
Price: $2,385.00
Insertion Electromagnetic flow transmitter, standard accuracy 4-36" (100-900 MM) pipe, 1% FS, 1" male NPT process connection, 1/2" female NPT conduit connection without cable Next Day* $2,385.00 Order
IEF-SN-CND-COM
Ships: Less Than 1 Week
Price: $2,841.00
Insertion Electromagnetic flow transmitter, standard accuracy 4-36" (100-900 MM) pipe, 1% FS, 1" male NPT process connection, 1/2" female NPT conduit connection without cable with BACnet/Modbus® communication output Less Than 1 Week* $2,841.00 Order
IEF-SN-CND-COM-LCD
Ships: Less Than 1 Week
Price: $3,221.00
Insertion Electromagnetic flow transmitter, standard accuracy 4-36" (100-900 MM) pipe, 1% FS, 1" male NPT process connection, 1/2" female NPT conduit connection without cable with BACnet/Modbus® communication output with LCD display Less Than 1 Week* $3,221.00 Order
IEF-SN-CND-LCD
Ships: Next Day
Price: $2,765.00
Insertion Electromagnetic flow transmitter, standard accuracy 4-36" (100-900 MM) pipe, 1% FS, 1" male NPT process connection, 1/2" female NPT conduit connection without cable with LCD display Next Day* $2,765.00 Order

Can't find what you need? Build Your Custom Part. Use our Product Configurator

Specifications

Service:
Compatible clean or dirty non coating, conductive liquids.
Range:
0 to 20 ft/s (0 to 6 m/s).
Wetted Materials:
Body shaft/fitting: 316SS; Electrodes: 316SS; Electrode cap: Polymer/Polystyrene; O-ring: Silicon.
Accuracy:
High accuracy units: ±0.5% of reading at calibrated velocity; ±1% of reading from 2 to 20 ft/s (0.6 to 6 m/s); ±0.02 ft/s (±0.006 m/s) at < 2 ft/s (0.6 m/s); Standard accuracy units: ±1% FS.
Temperature Limits:
Ambient: -20 to 160°F (-29 to 71°C); Process: 15 to 250°F (-9 to 121°C); Storage: -40 to 185°F (-40 to 85°C).
Process Connection:
1" NPT or BSPT with accessory full port ball valve options.
Pressure Limits:
400 psi (27.6 bar) @ 100º F (37.8°C).
Pressure Drop:
< 0.1 psi at 12 ft/s in 4" (101.6 mm) and larger pipe.
Outputs:
(1) Analog: 4 to 20 mA, 0 to 5 V, 0 to 10 V or 2 to 10 V (display selectable);
(1) Pulse/Frequency: 0 to 15 V peak pulse, 0 to 500 Hz or scalable pulse output (display selectable);
(2) Alarm: (1) Empty pipe detection or minimum/maximum velocity, (display selectable);
(1) Reverse flow output indication.
Power Requirements:
12 to 42.4 VDC, .25 A @ 24 VDC; 12 to 36 VAC.
Electrical Connection:
Removable terminal blocks, model selectable 1/2" female NPT conduit connection, PG 16 gland or PG 16 gland with (2) 10' (3 m) 9 conductor 22 AWG plenum rated cables, accessory cable lengths up to 200' (61 m) optional.
Display:
2" ( 5.08 cm) x 2" (5.08 cm) graphic LCD with backlight.
Conductivity:
>20 microsiemens.
Enclosure Material:
Powder coated die cast aluminum.
Enclosure Ratings:
NEMA 6P (IP68) (Non display models); NEMA 4X (IP66) (-LCD option).
Agency Approvals:
BTL, CE, NSF/ANSI 61 and 372.

COMMUNICATIONS (-COM OPTION)
Type:
BACnet MS/TP or Modbus® RTU communication protocol (default disabled, display selectable).
Supported Baud Rates:
9600, 19200, 38400, 57600, 76800, or 115200 bps (display selectable).
Device Load:
1/8 unit load.

ADDITIONAL SPECIFICATIONS
Applicable Pipe Material:
Most popular plastic and metal pipes; i.e. Carbon steel, SS, copper, UPVC/PVDF, galvanized steel, mild steel, and brass*.
Applicable Pipe Size:
4 to 36" (100 to 900 mm), model dependent. See model chart on catalog page.
Diameter Length Requirements:
>10 upstream, >5 downstream.

Glycol:
0 to 100% display selectable.
*Brass fittings and pipe not for use with NSF Certified models.

Features

  • Meet application requirements with field configurable setup displays (-LCD integral option or remote accessory A-IEF-DSP), which accommodate a variety of application configurations with one model through multiple display configurations i.e. pipe size, pipe material, liquid type, analog output, pulse/frequency output, alarm outputs, communication outputs, damping, and calibration factor
  • Maintain system efficiency with high performance accuracy that is maintained through changes in temperature, density or viscosity
  • Quick and easy ordering and set up with Setup Wizard and installation tool that are simple to use and allow for precise installation
  • Save time with accessory setup kit A-IEF-KIT that ensures exact installation application depth with included thickness gage and measuring tape
  • Reduced costs, long product life, and minimal maintenance requirements with no moving parts to wear or break and electrodes that discourage fouling
  • Minimize installation costs with isolation valve accessory options to allow for installation in operational systems via hot-tap kit or easy removal without system downtime
  • Required documents included with NIST traceable pass/fail verification certificate included standard for Carbon Steel Schedule 40 pipes sized 4" (102 mm), 6" (150 mm), 8" (200 mm)

Accessories

Model Number Description Usually Ships* Price Order
Set up kit, includes: set up display, measuring tape, universal power adapter for high accuracy installation and UTG thickness gage. A-IEF-KIT Set up kit, includes: set up display, measuring tape, universal power adapter for high accuracy installation and UTG thickness gage. 1-2 Weeks $1,462.00 Order
Setup display for field configuring non-display models. A-IEF-DSP Setup display for field configuring non-display models. 1-2 Weeks $805.00 Order
Plenum rated cable 50' (15.2 m). A-IEF-CBL-50 Plenum rated cable 50' (15.2 m). 1-2 Weeks $125.00 Order
Plenum rated cable 100' (30 m). A-IEF-CBL-100 Plenum rated cable 100' (30 m). 1-2 Weeks $250.00 Order
Plenum rated cable 150' (45 m). A-IEF-CBL-150 Plenum rated cable 150' (45 m). 1-2 Weeks $367.00 Order
1-1/4 A-IEF-VLV-BR 1-1/4" full port isolation valve brass kit. (Brass fittings and pipe not for use with NSF Certified models. Brass valves are non-RoHS compliant.) Next Day $331.00 Order
1-1/4 A-IEF-VLV-SS 1-1/4" full port isolation valve, 316SS kit. 12-13 Weeks $658.00 Order
Installation guide/alignment kit, includes: alignment scale body, 2 rods and 2 thumbscrews. A-IEF-INGD Installation guide/alignment kit, includes: alignment scale body, 2 rods and 2 thumbscrews. 1-2 Weeks $149.00 Order
A-IEF-TAG Meter tag, clear envelope tag for adding field configured information to unit. 1-2 Weeks $15.00 Order
Measuring tape used for circumference of the pipe. A-IEF-MSTP Measuring tape used for circumference of the pipe. 1-2 Weeks $89.00 Order
A-IEF-LKOUT Lock-out kit, includes: 4 specialty through hole screws for tamper evident locking of the display. 1-2 Weeks $44.50 Order
Ultrasonic Thickness Gage UTG Ultrasonic Thickness Gage Next Day $452.00 Order
Isolation valve kit, includes 316SS 1 A-IEF-VLV-SS-BSPT Isolation valve kit, includes 316SS 1" to 1-1/4" BSPT bushing, 316SS BSPT valve, 316SS BSPT threaded nipple with a 316SS BSPT threadolet. 6-7 Weeks $658.00 Order
Isolation valve kit, incl carbon steel 1 A-IEF-VLV-BR-BSPT Isolation valve kit, incl carbon steel 1" to 1-1/4" BSPT bushing, BSPT valve, BSPT threaded nipple with a BSPT threadolet, all brass. (Brass fittings and pipe not for use with NSF Certified models. Brass valves are non-RoHS compliant.) 9-10 Weeks $331.00 Order
Replacement blank lid, gasket and (4) screws. A-IEF-LID Replacement blank lid, gasket and (4) screws. 1-2 Weeks $89.00 Order
Full functional remote display for use with Series IEF. A-IEF-FDSP-RM Full functional remote display for use with Series IEF. 1-2 Weeks $1,097.00 Order
Indicating remote display for use with Series IEF. A-IEF-IDSP-RM Indicating remote display for use with Series IEF. 1-2 Weeks $733.00 Order
A-IEF-LCD LCD display to retrofit non-display models. 1-2 Weeks $440.00 Order
Plenum rated cable 200' (60 m). A-IEF-CBL-200 Plenum rated cable 200' (60 m). 1-2 Weeks $513.00 Order

Videos

Model Chart

IEF-XX-X-OPT IEF INSERTION MAG METER

1ST SYMBOL (1ST X) ACCURACY
     F    HIGH ACCURACY 4 IN PIPE ONLY (1% OF READING)
     I    HIGH ACCURACY 6 IN PIPE ONLY (1% OF READING)
     E    HIGH ACCURACY 8 IN PIPE ONLY (1% OF READING)
     T    HIGH ACCURACY 10 IN PIPE ONLY (1% OF READING)
     H    HIGH ACCURACY ALL SIZES 4-10 IN PIPE (1% OF READING)
     L    STANDARD ACCURACY 4-10 IN PIPE   (1% FULL SCALE)              
     G    STANDARD ACCURACY >10-36 IN PIPE (1% FULL SCALE)
     S    STANDARD ACCURACY 4-36 IN PIPE   (1% FULL SCALE)

2ND SYMBOL (2ND X) PROCESS CONNECTION 
     N     1 IN MALE NPT
     B     1 IN MALE BSPT 

3RD SYMBOL (3RD X) HOUSING ELECTRICAL CONNECTION 
     CND     1/2 IN FEMALE NPT CONDUIT CONNECTION W/O CABLE 
     PG      PG GLAND W/O CABLE 
     10      PG GLAND W/10 FT CABLE 

OPTIONS (OPT)
     -CC     CUSTOM CONFIGURATION *ADDITIONAL INPUT REQUIRED 
     -COM    BACNET/MODBUS COMMUNICATION 
     -FC     FACTORY CALIBRATION CERTIFICATE
     -LCD    LCD DISPLAY 
     -NIST   NIST CALIBRATION CERTIFICATE 
 


SlideShare

Approvals

Software

Drawings

Questions

Question
Are there any proven results?
Answer
No data available currently, but we are working with an outside lab to obtain this data.
Question
Is there a lockout feature to prevent setup changes?
Answer
Yes there is a switch that can be activated to ensure complete lockout of the display.
Question
Is there an adjustable BACnet baud rate?
Answer
Yes, baud rates 9600, 19200, 38400, 57600, 76800, or 115200 bps are selectable via the display.
Question
Do you go down to 2” pipe size?
Answer
The current minimum pipe size is 3” given customer configuration set up
Question
Is there BTU calculation?
Answer
In process with a first quarter 2019 release estimate.
Question
What is the difference between the standard accuracy, the high accuracy, and the custom configuration options?
Answer
The standard accuracy is 1% Full Scale, the high accuracy is 1% of reading in pipe sizes ranging from 4" to 10" outer diameter, and the custom configuration is a unit that comes preset for the application or for high accuracy applications where the outer pipe diameter is greater than 10".
Question
Why do I have to consult the factory for the high accuracy multi-pipe option?
Answer
The multi-pipe option must be calibrated for four different pipe sizes which takes substantially more time.
Question
Is there a valve kit suitable for potable water?
Answer
Yes, the stainless steel valve kit is suitable for potable water.
Question
What is included in the valve kit?
Answer
The valve kit includes a 1 1/4" ball valve, a reducer, a threadolet, a bushing, and a pipe nipple.
Question
Do I have to purchase an alignment guide separately?
Answer
No, every IEF includes an alignment guide.
Question
How long will it take to get a unit that is "out-of-stock"?
Answer
10 business days for both standard and high accuracy models.
Question
What is the difference between "Multi-Pipe" and custom configured?
Answer
Custom configured IEF's are only compatible with the one particular size they were calibrated for whereas "Multi-Pipe" models are compatible with the multiple size ranges that they were previously calibrated for.
Question
What does the term "Multi-Pipe" mean?
Answer
The term Multi-Pipe refers to one IEF unit across multiple pipes. For example, if a high accuracy model is calibrated for 4", 6", 8", and 10" pipe sizes, it can then be used in any or all of the sizes that were previously calibrated.
Question
Does the high accuarcy IEF need to be calibrated any differently then the standard IEF?
Answer
Yes, the high accuracy models must be wet calibrated in order to get within 1% of reading.
Question
What pipe sizes are compatible?
Answer
All IEF's are compatible with pipe sizes ranging from 4" to 36" outer diameter.

Photo Downloads

You must be logged in to view this content.
Click here to login to your account.

Product Reviews

Only registered users can write reviews. Please Sign in or create an account