Series AT-605 ATEX/IECEx Approved Magnehelic® Differential Pressure Indicating Transmitter
Series 605 in Flameproof ATEX/IECEx Enclosure
The Series AT-605 ATEX/IECEx Approved Magnehelic® Differential Pressure Indicating Transmitter provides for both visual monitoring and electronic control of very low differential pressure in hazardous locations. An easy-to-read dial gage is complimented by the two-wire, 4-20 mA control signal utilizing the time-proven Dwyer® Magnehelic® gage mechanical design and Series 600 transmitter technology. The two-wire design simplifies any 4-20 mA control loop powered by a 10-35 VDC supply. Flameproof enclosures are available in aluminum and can include a glass window for viewing process pressure on the gage face.
Important notes for installation:
• Cables must be fitted through 1/2" NPT cable gland or ATEX/IECEx conduit (not supplied
with instrument).
• Make sure after cabling to close tight cover and cable gland, in order to maintain IP66
rating.
• Open cover only after de-energizing instrument.
Attention: Check local safety rules and warnings on unit and manual for a correct
use of the instrument in hazardous areas.
Please see Series 605 for non-ATEX/IECEx approved.
Product Applications
- Monitor duct, room, or total building pressures
- Filter monitoring
- Local indication of clean room pressures with process signal sent to control room
- Hazardous area pressure measurement and transmitter
Models & Ordering
Specifications
- GAGE SPECIFICATIONS
- Service:
- Air and non-combustible, compatible gases.
- Wetted Materials:
- Consult factory.
- Accuracy:
- See page reference on catalog page.
- Pressure Limits:
- See pressure limit chart on catalog page.
- Temperature Limits:
- 20 to 120°F (-6.67 to 48.9°C) (Note: Product temperature limits differ from case).
- Size:
- 4" (101.6 mm) dial face.
- TRANSMITTER SPECIFICATIONS
- Accuracy:
- See page reference on catalog page. Includes linearity, hysteresis, repeatability.
- Compensated Temperature Range:
- 32 to 120°F (0 to 48.9°C).
- Thermal Effect:
- ±0.025% FS/°F (0.045% FS/°C).
- Stability:
- ±1% FS/year.
- Output Signal:
- 4-20 mA.
- Zero and Span Adjustments:
- Protected potentiometers on 605 face. Can access those by opening case. Allowed only in safe zone.
- Loop Resistance:
- DC: 0 to 1250 Ω max.
- Current Consumption:
- DC: 38 mA max.
- Electrical Connections:
- Screw terminal block.
- Mounting Orientation:
- Diaphragm in vertical position.
- Enclosure Rating:
- IP66 (IP65 for versions VS1/VS2/VL1).
- Housing Material:
- Aluminum.
- Finishing:
- Texture epoxy coat RAL7015.
- Process Connections:
- 1/8" NPT female brass (SS optional).
- Electrical Connections:
- Two 1/2" NPT female. Cable gland not included.
- Weight:
- 13.2 lb (6.0 kg).
- ATEX Certificate:
- INERIS 21ATEX0033X.
- IECEx Certificate:
- IECEx INE 21.0064X.
- Compliant:
- ATEX:
0080
II 2G Ex db IIC T5, T6 Gb -60°C ≤Ta ≤+50°C (T6) -60°C ≤Ta ≤+60°C (T5) II 2D Ex tb IIIC T75 °C Db;
IECEx: Ex db IIC T5, T6 Gb -60°C ≤Ta ≤+50°C (T6) -60°C ≤Ta ≤+60°C (T5) Ex tb IIIC T75°C Db.
Features
- ATEX/IECEx housing provides all the capabilities and values of the Series 605 Magnehelic® transmitter in a flame and explosion proof enclosure
- Quick response to pressure changes means no delay in assessing critical situations
- Durable and rugged housing and high-quality components combined provide longservice life and minimized downtime
- High impact strength and high temperature rated for applications where hazardous environments exist
- Increased response time at low pressures with LD port configuration
Model Chart
SERIES AT-605 PRESSURE TRANSMITTER AT-102NA-605-X-X-XXXX AT-605 PRESSURE XMTR W/ ATEX ENCL 1ST SYMBOL (1ST X) RANGE 00N 0.05 - 0 - 0.20 INWC 11 0.25 - 0 - 0.25 INWC 0 0 - 0.50 INWC 1 0 - 1.0 INWC 2 0 - 2.0 INWC 3 0 - 3.0 INWC 6 0 - 6.0 INWC 10 0 - 10 INWC 20 0 - 20 INWC 30 0 - 30 INWC 50 0 - 50 INWC 60PA 0 - 60 PA 125PA 0 - 125 PA 250PA 0 - 250 PA 500PA 0 - 500 PA 2ND SYMBOL (2ND X) HOUSING COVER B BLIND W GLASS WINDOW 3RD SYMBOL (3RD X) PRESSURE PORT/VENTING VALVE MATERIAL 1 BRASS 2 STAINLESS STEEL 4TH SYMBOL (4TH X) PRESSURE PRORT/VENTING VALVE VS0 STD PRESSURE PORT 1/8” FEMALE NPT/NO VENTING VALVE VL0 LD PRESSURE PORT 1/8” FEMALE NPT/NO VENTING VALVE VS1 STD PRESSURE PORT 1/8” FEMALE NPT/STD VENTING VALVE VS2 STD PRESSURE PORT 1/8” FEMALE NPT/LD VENTING VALVE VL1 LD PRESSURE PORT 1/8” FEMALE NPT/LD VENTING VALVE 5TH SYMBOL (5TH X) CABLE ENTRY 12 1/2" NPT ANSI/ASME B1.20.1
Approvals
Drawings
- VS0 (STD PORT/NO VALVE) .dwg
- VS0 (STD PORT/NO VALVE) .pdf
- VL0 (LD PORT/NO VALVE) .dwg
- VL0 (LD PORT/NO VALVE) .pdf
- VS1 (STD PORT/STD VALVE) .dwg
- VS1 (STD PORT/STD VALVE) .pdf
- VS2 (STD PORT/LD VALVE) .dwg
- VS2 (STD PORT/LD VALVE) .pdf
- VL1 (LD PORT/LD VALVE) .dwg
- VL1 (LD PORT/LD VALVE) .pdf
- VS0 (STD PORT/NO VALVE) w/WINDOW .dwg
- VS0 (STD PORT/NO VALVE) w/WINDOW .pdf
- VL0 (LD PORT/NO VALVE) w/WINDOW .dwg
- VL0 (LD PORT/NO VALVE) w/WINDOW .pdf
- VS1 (STD PORT/STD VALVE) w/WINDOW .dwg
- VS1 (STD PORT/STD VALVE) w/WINDOW .pdf
- VS2 (STD PORT/LD VALVE) w/WINDOW .dwg
- VS2 (STD PORT/LD VALVE) w/WINDOW .pdf
- VL1 (LD PORT/LD VALVE) w/WINDOW .dwg
- VL1 (LD PORT/LD VALVE) w/WINDOW .pdf
Photo Downloads
You must be logged in to view this content.Click here to login to your account.