Series DCTE Photohelic® Switch/Gage On-Demand Cleaning Controller
Reverse Pulse-Jet Cleaning Initiated by Differential Pressure
The Photohelic® Pressure Switch/Gages On-Demand Cleaning Controller provides a simple, complete dust collection control all in one enclosure. The Photohelic® controller combined with the DCT500DC Timer Control provides a timed energization of solenoid valves when the differential pressure indicates filter cleaning is necessary. The operator can easily set the cleaning initiation and duration by adjusting the 2 set point knobs on the front face of the Photohelic® controller. Solenoid valve sequencing is also easily set via two potentiometers inside the enclosure on the timer board. A three position switch on the front of the enclosure offers cleaning versatility by allowing the user to select between on demand or continuous manual cleaning. The Photohelic® controller is pneumatically connected with tubing to fittings on the enclosure. All that is required for start-up is connection of tubing from the process to the external fittings on the enclosure, and wiring the solenoid valves to the timer board.
NIST CALIBRATION available in Product Configurator.
Models & Ordering
Specifications
- DCT500DC SPECIFICATIONS
Output Channels: 4, 6, & 10 channels.
Power Requirements: 10 to 35 VDC, 0.6 watt max. no load power. 120 Volt powered timer board also available.
Solenoid Supply: 3A max. per channel.
Fuse: Type 3 AG, 3A @ 250 VAC.
Temperature Limits: -40 to 176°F (-40 to 80°C).
Storage Temperature Limits: -40 to 176°F (-40 to 80°C).
On Time: 50 msec to 500 msec.
On Time Accuracy: ±5% of setting.
Off Time: 1 second to 200 seconds.
Off Time Accuracy: ±5% of setting.
Weight: 9 oz (255 g).PHOTOHELIC® SPECIFICATIONS GAGE SPECIFICATIONS
Service: Air and non-combustible, compatible gases.
Wetted Materials: Consult factory.
Accuracy: ±2% of full scale.
Pressure Limits: -20" Hg to 25 psig (-0.677 bar to 1.72 bar). MP option: 35 psig (2.41 bar); HP option: 80 psig (5.52 bar).
Temperature Limits: 20 to 120°F (-6.67 to 48.9°C).
Process Connections: 1/8" female NPT (duplicated side and back).
Size: 4" (101.6 mm) dial face, 5" (127 mm) O.D. x 3-1/8" (79.38 mm).
Weight: 1.8 lb (816 g).SWITCH SPECIFICATIONS 3000MR
Switch Type: Each setpoint has a 1 Form C relay (SPDT).
Relay Contacts: (resistive load) 1 Form C rated 1.0A @ 30 VDC, 0.3A @ 110 VDC or 0.5A @ 125 VAC. Gold over clad silver - suitable for dry circuits.
Electrical Connections: 18" (46 cm) cable assembly with 8 conductors. Optional lengths to 100' (30.5 m).
Power Requirements: 24 VDC, regulated ±10%.
Mounting Orientation: Diaphragm in vertical position. Consult factory for other position orientations.
Set Point Adjustment: Adjustable knobs on face.
Features
- External, manual adjustment of set points with Photohelic® controller adjustment knobs.
- On and off time easily set with 2 potentiometers located on the DCT500DC timer board.
- 3 position switch for selecting between On-Demand Cleaning or continuous manual cleaning.
- Photohelic® controller pre-connected with tubing to pressure fittings on body of enclosure.
Model Chart
EXAMPLE | DCTE504A | 3000MR-0 | AT | Series DCTE504A-3000MR-0-AT Photohelic® Pressure Switch/Gage On-Demand Cleaning Controller, range 0-0.5" w.c., 4 channels, with aluminum tag. |
SERIES | DCTE504A DCTE506A DCTE510A DCTE504ADC DCTE506ADC DCTE510ADC DCTE604 DCTE606 DCTE610 DCTE622 DCTE632 DCTE1006 DCTE1010 DCTE1022 |
4 Channel 6 Channel 10 Channel 4 Channel, DC 6 Channel, DC 10 Channel, DC 4 Channel, 120-240 Universal Power Supply 6 Channel, 120-240 Universal Power Supply 10 Channel, 120-240 Universal Power Supply 22 Channel, 120-240 Universal Power Supply 32 Channel, 120-240 Universal Power Supply 6 Channel 10 Channel 22 Channel |
||
PHOTOEHELIC® GAGE |
3000MR-0 3001MR 3002MR 3003MR 3005MR 3010MR 3015MR 3020MR 3030MR 3050MR 3100MR 3000MR-6MM 3000MR-10MM 3000MR-25MM 3000MR-50MM 3000MR-100MM 3000MR-20CM 3000MR-60PA 3000MR-125PA 3000MR-250PA 3000MR-500PA 3000MR-1KPA 3000MR-3KPA 3000MR-4KPA |
0-0.5" w.c. 0-1" w.c. 0-2" w.c. 0-3" w.c. 0-5" w.c. 0-10" w.c. 0-15" w.c. 0-20" w.c. 0-30" w.c. 0-50" w.c. 0-100" w.c. 0-6 mm w.c. 0-10 mm w.c. 0-25 mm w.c. 0-50 mm w.c. 0-100 mm w.c. 0-20 cm w.c. 0-60 Pa 0-125 Pa 0-250 Pa 0-500 Pa 0-1 kPa 0-3 kPa 0-5 kPa |
||
OPTIONS | AT NIST ST |
Aluminum Tag NIST Certification Stainless Steel Tag |
Drawings
Questions
- Question
- What restrictions, if any, are imposed for the Magnehelic® and Photohelic® gages in vacuum service?
- Answer
- In applications involving higher vacuums than 20" Hg, leakage due to gage housing porosity becomes the limiting factor.
Photo Downloads
You must be logged in to view this content.Click here to login to your account.